Fully Automatic Dynamic Mechanical Analyzer (DMA)

Giá bán: Call

Mã sản phẩm: VR-7130

Thương hiệu: Ueshima

Bảo hành: 12 month

Fully Automatic Dynamic Mechanical Analyzer (DMA) Model VR-7130 was designed to minimize possible causes of measurement errors and variability by adopting the full automatic system and the unique temperature sensor. In combination with THERMO JETTER, it can measure viscoelasticity down to -90°C (-100°C as an option) without using liquid nitrogen.

Specefications                                                                  

 

Name

Fully Automatic Viscoelasticity Analyzer

Model

VR-7130

Sample dimensions

Rectangular shape 40(L) x 4(W) x 2(t) mm

Testing method

Vertical tensile method

Chucking method

Constant pressure tightening by spring structure

Sample convey system

Automatic: 100 samples max.

Distance between chucks

20mm (Option: 10mm)

 

Load detection

  1. Load detector: Piezoelectric type load cell (Choose rating: ±45N or ±450N)
  2. Maximum load: 200N (with Load cell ±450N)
  3. Resolution: 1% F.S.

 

Displacement detection

  1. Displacement sensor: Optical fiber, non-contact type small displacement sensor
  2. Maximum displacement: 1,000μm
  3. Resolution: 0.3μm

 

 

Vibrator

  1. Vibration system: Electric vibrator (Lower chuck drive)
  2. Vibration waveform: Sinusoidal wave
  3. Vibration frequency: 0.1 to 200Hz continuously variable
  4. Vibration amplitude (strain): ±0.1 to ±2.5% (40 to 1,000μm p-p) continuously variable (±0.2 to ±5% in case of 10-mm chuck distance)

 

Initial tension

  1. Mechanism: Lower side chuck tension by the vibrator
  2. Method: Constant strain method, constant load method (calculated to strain)
  3. Tension: 0μm to 2,000μm

Thermostatic chamber

Framework: Opens and closes automatically

Testing temperature range

-90 to 200°C (optionally down to -100°C without using liquid nitrogen)

 

Safety device

  1. Emergency stop switch
  2. Overheat limiter
  3. Pneumatic limiter
  4. Ground-fault circuit breaker

Connection for control

  1. Main unit control: USB
  2. Temperature control: RS-232C (D-SUB 9pin)

 

Utilities

  1. Main unit: Power source AC100V 1-phase 2kVA Dry air 0.4MPa
  2. Cold air generator:Power source AC200V 3-phase 4kVA

Dry air 0.5MPa Flow rate 250L/min

Usage environment

  1. Temperature : 5 to 40°C
  2. Humidity : 35 to 80%RH

Dimensions

Main unit and the rack: approx. 470 (W) x 470 (D) x 1320 (H) mm

Thermo Jetter (cooling air generator): approx. 510 (W) x 740 (D) x 1110 (H) mm

Accessories

Load calibration tool, tool set and connection cables

 

 Options                                                                            

  • Master curve software
  • Temperature/strain dispersion, Temperature/frequency dispersion
  • Sample cutting blade, the exchangeable blade type

Specefications                                                                  

 

Name

Fully Automatic Viscoelasticity Analyzer

Model

VR-7130

Sample dimensions

Rectangular shape 40(L) x 4(W) x 2(t) mm

Testing method

Vertical tensile method

Chucking method

Constant pressure tightening by spring structure

Sample convey system

Automatic: 100 samples max.

Distance between chucks

20mm (Option: 10mm)

 

Load detection

  1. Load detector: Piezoelectric type load cell (Choose rating: ±45N or ±450N)
  2. Maximum load: 200N (with Load cell ±450N)
  3. Resolution: 1% F.S.

 

Displacement detection

  1. Displacement sensor: Optical fiber, non-contact type small displacement sensor
  2. Maximum displacement: 1,000μm
  3. Resolution: 0.3μm

 

 

Vibrator

  1. Vibration system: Electric vibrator (Lower chuck drive)
  2. Vibration waveform: Sinusoidal wave
  3. Vibration frequency: 0.1 to 200Hz continuously variable
  4. Vibration amplitude (strain): ±0.1 to ±2.5% (40 to 1,000μm p-p) continuously variable (±0.2 to ±5% in case of 10-mm chuck distance)

 

Initial tension

  1. Mechanism: Lower side chuck tension by the vibrator
  2. Method: Constant strain method, constant load method (calculated to strain)
  3. Tension: 0μm to 2,000μm

Thermostatic chamber

Framework: Opens and closes automatically

Testing temperature range

-90 to 200°C (optionally down to -100°C without using liquid nitrogen)

 

Safety device

  1. Emergency stop switch
  2. Overheat limiter
  3. Pneumatic limiter
  4. Ground-fault circuit breaker

Connection for control

  1. Main unit control: USB
  2. Temperature control: RS-232C (D-SUB 9pin)

 

Utilities

  1. Main unit: Power source AC100V 1-phase 2kVA Dry air 0.4MPa
  2. Cold air generator:Power source AC200V 3-phase 4kVA

Dry air 0.5MPa Flow rate 250L/min

Usage environment

  1. Temperature : 5 to 40°C
  2. Humidity : 35 to 80%RH

Dimensions

Main unit and the rack: approx. 470 (W) x 470 (D) x 1320 (H) mm

Thermo Jetter (cooling air generator): approx. 510 (W) x 740 (D) x 1110 (H) mm

Accessories

Load calibration tool, tool set and connection cables

 

 Options                                                                            

  • Master curve software
  • Temperature/strain dispersion, Temperature/frequency dispersion
  • Sample cutting blade, the exchangeable blade type

Bình luận

FPS Abrasion Tester

Ueshima - Japan
12 tháng12 months

DEMATTIA FLEX CRACKING TESTER

Ueshima - Japan
12 tháng12 months
Xem tất cả 9 Sản phẩm liên quan

Statistical access

  • Đang online 228
  • Hôm nay 2008
  • Hôm qua 1954
  • Trong tuần 112094
  • Trong tháng 411825
  • Tổng cộng 5567811
COPYRIGHT BY CÔNG TY TNHH THIẾT BỊ SECOVINA
Design by Mulplat