Rubber anf Plastic GEER’S AGING OVEN

Giá bán: Call

Mã sản phẩm: AG-1110/1115

Thương hiệu: Ueshima - Japan

Bảo hành: 12 Months

Ueshima AG1110/AG1115 GEER’S AGING OVEN Most important functions like temperature uniformity, wind velocity and air ventilation rate are in accordance with JIS K 6257 and/or JIS K 7212. ○The minimized shape of the series allows use on a table. We also provide with an exclusive stand. ○It is able to place two units in tiers, minimizing the footprint.

 

MODEL

For Rubber & Plastics

For Plastics

Standard

Large Type

Standard

Large Type

 

(*1)

Analog  Setting

AG-1110

AG-1115

AG-1120

AG-1125

Digital Setting

AG-1210

AG-1215

AG-1220

AG-1225

Applicable Standard

JIS K 6257, ISO 188, JIS K 7212 B Type

JIS K 7212, ISO 4577

Chamber Dimensions (mm)

W450 x D450 x H500

W600 x D600 x H600

W450 x D450 x H500

W600xD600xH600

Chamber Material

Stainless Steel (SUS 304)

Temperature Range

40 to 300ºC

Temperature Control

Temperature controller with digital display, PID with auto tuning

Temperature Sensor

Resistance thermometer  bulb (Pt100Ω, 3.2-mm dia. x 350mm)

Temperature Sensor

Platinum resistance temperature  detector

Pt 100Ω,φ3.2 x250(L)

Pt 100Ω,φ3.2 x300(L)

Pt 100Ω,φ3.2 x250(L)

Pt100Ω,φ3.2 x300(L)

Heater

1-ph 200V, 3kW

3-ph 200V, 6kW

1-ph 200V, 3kW

3-ph 200V, 6kW

Circulation Fan Motor

200VAC, 0.2kW

Temperature Rising Time

Within 45 min. from RT to 300ºC

Temperature Uniformity

Within ±1ºC (40~100ºC), ±1% (at 100 ºC or higher)

Average Wind Speed

0.5±0.1m/sec(*2)

1.0±0.2m/sec(*3)

Ventilation Rate

3 to 10 times/hour (variable) (*2)

5 to 60 times/hour (variable) (*3)

Sample Hanger Rotation

6~8 rpm

 

 

Safety Device

(a) Leakage breaker: protection of short circuit, overcurrent

(b) Overheat protector: default set to 325ºC, causes  power  shut down

(c) Overload protection of circulation fan motor

Accessories

Single shaft two stage sample hanging frame, sample clip, glass fuse

 

Power Supply Required

1-ph 200VAC, 20A

50Hz or 60Hz

3-ph 200VAC, 30A

50Hz or 60Hz

1-ph 200VAC, 20A

50Hz or 60Hz

3-ph 200VAC, 30A

50Hz or 60Hz

Outer Dimensions (mm)

W1050x D720xH860

W1250xD910xH990

W1050xD720xH860

W1250xD910x H990

Option Stand(mm)

optional shelf board, optional exclusive stand(H:835mm(Standard),825mm(Large Type))

 

*1) Setting Method  of Ventilation Rate
Analog  Setting  : Setting by a lever
Digital Setting    : Digital settings on front panel
*2) By JIS K 6257
*3) By JIS K 7212 “Wind Speed and Ventilation Rate”, A type.

 

Nội dung chi tiết thông số kỹ thuật sản phẩm đang được cập nhật...

Nội dung chi tiết video sản phẩm đang được cập nhật...

Nội dung chi tiết download đang được cập nhật...

Nội dung chi tiết phụ kiện sản phẩm đang được cập nhật...

Bình luận

Fully Automatic Dynamic Mechanical Analyzer (DMA)

Ueshima
12 tháng12 month

rubber Blow Point Analyzer

Ueshima - Japan
12 tháng12 Months
Xem tất cả 5 Sản phẩm liên quan

Statistical access

  • Đang online 64
  • Hôm nay 2309
  • Hôm qua 4580
  • Trong tuần 77487
  • Trong tháng 299580
  • Tổng cộng 3189717
COPYRIGHT BY CÔNG TY TNHH THIẾT BỊ SECOVINA
Design by 1Onnet